Set Ascending Direction
per page
View as Grid List
Rating:
0%
Ariston
250
AT3069776AT3069776
"

Product Details

  • COP: 3.35
  • Heating Time: 05:23 h.min
  • Seasonal Yield (Average Climate): 138%
  • Min/Max Air Temperature: -7 to 42 °C
  • Max Water Temperature (Heat "i>Maximum Working Pressure: 6 bars
  • Maximum Absorbed Voltage/Power: 220-240V/W
  • Resistance Power: 1500 + 1000 W
  • Standard Airflow (Auto Modulation): 650 m3/h
  • Minimum Volume of theInstallation Room: [Not specified]
  • Empty Mass: 95 kg
  • Electrical Protection: IPX4
  • Insulation Thickness: 50 mm
  • Diameter of Water Connections: 3/4
  • Minimum Temperatureof the Accumulation Room: 1°C
  • Exchanger Surface: [Not specified]
  • Thermal Dispersions (Pes): 22 W
  • Available Static Pressure: 110 Pa
  • Minimum Volume of the Installation Room: 30m3
  • Article Number: 3069776

Product Description

  • Integrated Wi-Fi for remote management via APP
  • Compatible with Bus BridgeNET for integration with complex systems
  • Shortest heat-up time in its category
  • Working range in heat pump with air temperatures from 5 to 42°C
  • Water temperature up to 62°C with the heat pump only
  • Electric resistance in steatite with double power (1500 W + 100 W)
  • One or two additional coils and probe holder for solar, boiler, or biomass integration
  • OHW recirculation (model SYS and TWIN SYS)
  • Active anode (protech) magnesium anode
  • Internal installation
  • First ignition free
Rating:
0%
Ariston
200
AT3069775AT3069775
"

Product Details

  • COP: 3.1
  • Heating Time: 03:59 h:min
  • Seasonal Yield (Average Climate): 130%
  • Min/Max Air Temperature: -71 to 42 °C
  • Max Water Temperature (Heat ">Maximum Working Pressure: 6 bars
  • Maximum Absorbed Voltage/Power: 220-240V/1250 W
  • Resistance Power: 1500+1000 W
  • Standard Airflow (Auto Modulation): 650 m3/h
  • Minimum Volume of the Installation Room: 30 m3
  • Empty Mass: 90 kg
  • Electrical Protection: IPX4
  • Insulation Thickness: 50 mm
  • Diameter of Water Connections: 3/4
  • Minimum Temperature of theAccumulation Room: 1°C
  • Exchanger Surface: [Not specified]
  • Thermal Dispersions (Pes): 21 W
  • Available Static Pressure: 110 Pa
  • Minimum Volume of the Installation Room: 30 m3
  • Article Number: 3069775

Product Description

  • Integrated Wi-Fi for remote management via APP
  • Compatible with Bus BridgeNET for integration with complex systems
  • Shortest heat-up time in its category
  • Working range in heat pump with air temperatures from 5 to 42°C
  • Water temperature up to 62°C with the heat pump only
  • Electric resistance in steatite with double power (1500 W + 1000 W)
  • One or two additional coils and probe holder for solar, boiler, or biomass integration
  • OHW recirculation (model SYS and TWIN SYS)
  • Active anode (protech)magnesium anode
  • Internal installation
  • First ignition free
Rating:
0%
Ariston
80
AT3629056AT3629056

Product Details

  • COP (A): 2.83
  • COP (B): 2.6
  • Heating time (A): 4:38 hh:mm
  • Min/max air temperature: -5/42 °C
  • Max water temperature heat pump only mode: 62/75 °C
  • Sound power (D): 50 dB(A)
  • Average electrical power consumption in heat pump mode: 250 W
  • Max electrical power consumption in heat pump mode: 350 W
  • Max Qty of domestic hot water at 40°C (B): 85 I
  • Nominal storage tank capacity: 80 I
  • Max operating pressure: 8 bar
  • Voltage/Max. power consumption: 220-240 V single-phase / 1550 W
  • Heating element power: 1200 W
  • Standard air flow rate: 100-200 m³/h
  • Min volume of the installation room: 20 m³/h
  • Empty weight: 50 kg
  • Electricalsystem protection grade: IP24
  • Insulation thickness: 41 mm
  • Water connections diameter: 1/2 M
  • Min Temperature of storage tank room: 1 °C
  • Heat dispersion (Pes) (B): 12 W
  • Available static pressure: 65 Pa
  • Annual energy consumption (average climate): 479 kWh/year
  • Seasonal efficiency (C): 107.1%
  • GWP: 1430
  • CO2 equivalents: 0.543 t
  • Article Number: 3629056

Product Description

  • Top of the range wall-hung heat pump for domestic hot water production in A+ class.
  • High performances and sustainability: environmentally friendly heat pump mode to achieve 62°C.
  • Security and durability: Condenser wrapped around titanium enamelled steel boiler, not immersed in water.
  • Operating range in heat pump mode with air temperature from -5 to 42°C
Rating:
0%
Ariston
From [110] to [150]
AT3629057AT3629057
"

Product Details

  • COP': 2.45
  • COP"": 2.7
  • Heating Time': 8:04 hrs:mins
  • Seasonal Yield: 102%
  • Min/Max Air Temperature: -5 to 42°C
  • Max Water Temperature "tity of Hot Water at 40°C: 1281
  • Storage Nominal Capacity: 1101
  • Maximum Working Pressure: 8 bars
  • Maximum Absorbed Voltage/Power: 220-240/1550 V/W
  • Resistance Power: 1200 W
  • Standard Air Flow: 100-200 m3/h
  • Minimum Volume of the Installation Room': 20 m3
  • Empty Mass: 55 kg
  • Electrical Protection: IP24
  • Insulation Thickness: 41 mm
  • Diameter of Water Connections: 1/2""
  • Minimum Temperature of the Accumulation Room: 1°C
  • Thermal Dispersions (Pes)*: 17 W
  • Available Static Pressure: 65 Pa
  • Article Number: 3629057

Product Description

  • Working Range in Heat Pump with Air Temperatures from -5 to 42°C
  • Super Silent Operation Thanks to the Silent Function: 50 dB
  • Titanium Enamelled Steel Boiler
  • Internal Installation
Rating:
0%
Ariston
80
AT3623242AT3623242

Product Details

  • COP (A): 2.4
  • COP (B): 2.04
  • Heating time (A): 02:39 hh:mm
  • Min/max air temperature: -5/42°C
  • Max water temperature heat pump only mode: 62/75°C
  • Sound power U.I. (D): 15 dB(A)
  • Sound power U.E. (D): 57 dB(A)
  • Avg. electrical power consumption in heat pump mode: 510 W
  • Nominal storage tank capacity: 80 l
  • Max operating pressure: 8 bar
  • Voltage/Max. power consumption: 220-240 V/W 1950
  • Heating element power: 1200 W
  • Empty weight: 32 kg
  • Electrical system protection grade:IP24
  • Insulation thickness: 41 mm
  • Water connections diameter: 1/2 M
  • Min Temperature of storage tank room: 1°C
  • Heat dispersion (Pes) (B): 20 W
  • Annual energy consumption (average climate) (C): 606 kWh/year
  • Seasonal efficiency (C): 85%
  • V40 (Qty of mixed DHWat 40°C) (C): 99 l
  • Article Number: 3623242

Outdoor Unit

  • Refrigerant circuit connections diameter: 1/4 3/8 with bell end
  • Empty weight: 27 kg
  • Standard air flow rate: 1100 m³/h
  • Max pressure in the refrigerating circuit (Low p side): 12 bar
  • Max pressure in refrigerating circuit (High p side): 27 bar
  • Electrical system protection grade: IP24

Product Description

  • Condenser wrapped around titanium enamelled steel boiler, not immersed in water
  • Operating range in heat pump mode with air temperature from -5 to 42°C
  • Active anode Protech + magnesium anode
  • Tank intended for indoor installation
Rating:
0%
Ariston
240
AT3069655AT3069655

Product Details

  • COP (A): 3.06
  • COP (B): 2.77
  • Heating Time (B): 7:57 hh:mm
  • Min/Max Air Temperature: -5/42 °C
  • Max Water Temperature Heat Pump Only Mode: 55/75 °C
  • Sound Power (D): 53 dB(A)
  • Average Electrical Power Consumption in Heat Pump Mode: 500 W
  • Nominal Storage Tank Capacity: 239 I
  • Max Operating Pressure: 6 bar
  • Voltage/Max. Power Consumption: 220-230/2750 V/W
  • Heating Element Power: 2000 W
  • Standard Air Flow Rate: 400 m³/h
  • Min Volume of the Installation Room (E): 20 m³
  • Empty Weight: 107 kg
  • Electrical System Protection Grade: IP24
  • Insulation Thickness: 35 mm
  • Water Connections Diameter: G 3/4 M
  • Min Temperature of Storage Tank Room: 1 °C
  • Heat Exchanger Surface Area: 0.65 m²
  • Heat Dispersion (Pes) (B): 35 W
  • Available Static Pressure: 55 Pa
  • Annual Energy Consumption (Average Climate) (C): 1470 kWh/year
  • Seasonal Efficiency: 114%
  • Article Number: 3069655

Product Description

  • Floor-standing heat pump for domestic hot water production
  • High performances and sustainability: environmental friendly heat pump mode to achieve 55°C.
  • Features
    • Operating range in heat pump mode with air temperature from -5 to 42°C
    • Coils and sensors slot to integrate solar thermal or boiler (240 SYS)
    • Active anode Protech + magnesium anode
    • LCD display
    • Modes: green, auto, boost, program
    • Antilegionella
    • Product intended for indoor installation
Rating:
0%
Ariston
80
AT3623238AT3623238

Product Details

  • COP (A): 2.32
  • Heating time (A): 5:20 hh:mm
  • Min/max air temperature: Oct-40°C
  • Max water temperature heat pump only mode: 55°C
  • Sound power (c): 54 dB(A)
  • Average electrical power consumption in heat pump mode: 250 W
  • Max Qty of domestic hot water at 40°C (B): 91 l
  • Nominal storage tank capacity: 80 l
  • Max operating pressure: 8 bar
  • Voltage/Max. power consumption: 220-240 V/W single-phase
  • Heating element power: 1200 W
  • Standard air flow rate: 170 m³/h
  • Min volume of the installation room: 20 m³
  • Empty weight: 45 kg
  • Electrical system protection grade: IP24
  • Insulation thickness: 31 mm
  • Water connections diameter: 1/2 M
  • Min Temperature of storage tank room: 1°C
  • Heat dispersion (Pes) (A): 17 W
  • Available static pressure: 65 Pa
  • Annual energy consumption (average climate) (B): 533 kWh/year
  • Seasonal efficiency (B): 96.4%
  • Article Number: 3623238

Product Description

  • Wall-hung heat pump for domestic hot water production
  • High performances and sustainability: environmental friendly heat pump mode to achieve 55°C.
  • Security and durability: Condenser wrapped around titanium enamelled steel boiler, not immersed in water.

Features

  • Operating range in heat pump mode with air temperature from 10 to 40°C
  • Anti corrosion magnesium anode
  • LED display
  • Modes: green, auto, boost, program
  • Antilegionella
  • Product intended for indoor installation
Rating:
0%
Ariston
250
AT3069778AT3069778

Product Details

  • COP (A): 3.62
  • COP (B): 3.21
  • Heating Time (A): 4:37 hh:mm
  • Min/Max Air Temperature: -10/42 °C
  • Max Water Temperature Heat Pump Only Mode: 62/75 °C
  • Sound Power (C): 55 dB(A)
  • Sound Power (Silent Mode) (C): 51 dB(A)
  • Max Electrical Power Consumption in Heat Pump Mode: 900 W
  • Nominal Storage Tank Capacity: 240 I
  • Max Operating Pressure: 6 bar
  • Voltage/Max Power Consumption: 220-240/2500 W
  • Heating Element Power: 1500 + 1000 W
  • Standard Air Flow Rate: 650 m³/h
  • Min Volume of the Installation Room (E): 30 m³
  • Empty Weight: 130 kg
  • Electrical System Protection Grade: IPX4
  • Insulation Thickness: 50 mm
  • Water Connections Diameter: G 3/4 M
  • Min Temperature of Storage Tank Room: 1 °C
  • Heating Bottom Circuit Exchange Surface: 0.65 m²
  • Heating Top Circuit Exchange Surface: 0.65 m²
  • Heat Dispersion (Pes) (B): 25 W
  • Available Static Pressure: 230 Pa
  • Annual Energy Consumption (Average Climate) (C): 1256 kWh/year
  • Seasonal Efficiency (C): 133%
  • V40 (Qty of Mixed DHW at 40°C) (C): 325 I
  • Energy Class: A+
  • Tapping Profile: XL
  • Article Number: 3069778

Product Description

  • Top of the range floor-standing heat pump for domestic hot water production in A+ class, with connectivity.
  • Full comfort with lowest heating time on market* and superior COP.
  • Simplified control via smartphone with Aqua Ariston NET app.
  • High performances
Rating:
0%
Ariston
150
AT3629074AT3629074

Product Details

  • COP (A): 3,15
  • COP (B): 2,9
  • Heating time (A): 08:56 hh:mm
  • Min/max air temperature: -5/42°C
  • Max water temperature heat pump only mode: 62/75°C
  • Sound power (D): 50 dB(A)
  • Average electrical power consumption in heat pump mode: 250 W
  • Max electrical power consumption in heat pump mode: 350 W
  • Max Qty of domestic hot water at 40°C (B): 182 l
  • Nominal storage tank capacity: 147 l
  • Max operating pressure: 8 bar
  • Voltage/Max. power consumption: phase/1550 V/W
  • Heating element power: 1200 W
  • Standard air flow rate: 100-200 m³/h
  • Min volume of the installation room: 20 m³
  • Empty weight: 61 kg
  • Electrical system protectiongrade: IP24
  • Insulation thickness: 41 mm
  • Water connections diameter: 1/2 M 1/2 M 1/2 M
  • Min Temperature of storage tank room: 1°C
  • Heat dispersion (Pes) (B): 20 W
  • Available static pressure: 65 Pa
  • Annual energy consumption (average climate) (C): 858 kWh/year
  • Seasonal efficiency (C): 119,3%
  • Article Number: 3629074

Product Description

  • Wall-hung heat pump for domestic hot water production in A+ class
  • High performances and sustainability: environmental friendly
  • Condenser wrapped around titanium enamelled steel boiler, not immersed in water.
  • Operating range in heat pump mode with air temperature from -5 to 42°C
  • Active anode Protech + magnesium anode
  • Low noise in silent mode
  • Modes: green, auto, boost, boost 2, holiday and antilegionella modes
  • Indoor installation
Rating:
0%
Ariston
250
AT3069777AT3069777

Product Details

  • COP (A): 3.62
  • COP (B): 3.14
  • Heating Time (A): 4:37 hh:mm
  • Min/Max Air Temperature: -10/42 °C
  • Max Water Temperature Heat Pump Only Mode: 62/75 °C
  • Sound Power (C): 55 dB(A)
  • Sound Power (Silent Mode) (C): 51 dB(A)
  • Max Electrical Power Consumption in Heat Pump Mode: 900 W
  • Nominal Storage Tank Capacity: 245 I
  • Max Operating Pressure: 6 bar
  • Voltage/Max Power Consumption: 220-240/2500 W
  • Heating Element Power: 1500 + 1000 W
  • Standard Air Flow Rate: 650 m³/h
  • Min Volume of the Installation Room (E): 30 m³
  • Empty Weight: 115 kg
  • Electrical System Protection Grade: IPX4
  • Insulation Thickness: 50 mm
  • Water Connections Diameter: G 3/4 M
  • Min Temperature of Storage Tank Room: 1 °C
  • Heating Bottom Circuit Exchange Surface: 0.65 m²
  • Heating Top Circuit Exchange Surface: 0.65 m²
  • Heat Dispersion (Pes) (B): 23 W
  • Available Static Pressure: 230 Pa
  • Annual Energy Consumption (Average Climate) (C): 1299 kWh/year
  • Seasonal Efficiency (C): 129%
  • V40 (Qty of Mixed DHW at 40°C) (C): 333 I
  • Energy Class: A+
  • Tapping Profile: XL
  • Article Number: 3069777

Product Description

  • Top of the range floor-standing heat pump for domestic hot water production in A+ class, with connectivity.
  • Full comfort with lowest heating time on market* and superior COP.
  • Simplified control via smartphone with Aqua Ariston NET app.
  • High performances
Rating:
0%
Ariston
110
AT3623243AT3623243

Product Details

  • COP (A): 2.37
  • COP (B): 2.03
  • Heating Time (A): hh:mm 3:49
  • Min/Max Air Temperature: -5/42 °C
  • Max Water Temperature Heat Pump Only Mode: 62/75 °C
  • Sound Power U.I. (D): 15 dB(A)
  • Sound Power U.E. (D): 57 dB(A)
  • Average Electrical Power Consumption in Heat Pump Mode: 510 W
  • Nominal Storage Tank Capacity: 110 I
  • Max Operating Pressure: 8 bar
  • Voltage/Max. Power Consumption: 220-240/1950 V/W
  • Heating Element Power: 1200 W
  • Empty Weight: 38 kg
  • Electrical System Protection Grade: IP24
  • Insulation Thickness: 41 mm
  • Water Connections Diameter: 1/2 M
  • Min Temperature of Storage Tank Room: 1 °C
  • Heat Dispersion (Pes) (B): 24 W
  • Annual Energy Consumption (Average Climate) (C): 604 kWh/year
  • Seasonal Efficiency (C): 84.8 %
  • SeasonalEfficiency: 139 I
  • Article Number: 3623243

Outdoor Unit

  • Refrigerant Circuit Connections Diameter: 1/4 3/8 with bell end
  • Empty Weight: 27 kg
  • Standard Air Flow Rate: 1100 m³/h
  • Max Pressure in the Refrigerating Circuit (Low P Side): 12 bar
  • Max Pressure in Refrigerating Circuit (High P Side): 27 bar
  • Electrical System Protection Grade: IP24
  • Max Distance Between Storage Tank and Outdoor Unit: 8 m
  • Max Difference in Level Between Storage Tank and Outdoor Unit: 3 m

Product Description

  • Split wall-hung heat pump for domestic hot water production
  • High performance
Rating:
0%
Ariston
100
AT3623239AT3623239

Product Details

  • COP (A): 2.17
  • Heating time (A): 6:36 hh:mm
  • Min/max air temperature: Oct-40 °C
  • Max water temperature heat pump only mode: 55 °C
  • Sound power (c): 54 dB(A)
  • Average electrical power consumption in heat pump mode: 250 W
  • Max Qty of domestic hot water at 40°C (B): 117 I
  • Nominal storage tank capacity: 100 I
  • Max operating pressure: 8 bar
  • Voltage/Max. power consumption: 220-240 V single-phase / 1550 W
  • Heating element power: 1200 W
  • Standard air flow rate: 170 m³/h
  • Min volume of the installation room: 20 m³
  • Empty weight: 49 kg
  • Electrical system protection grade: IP24
  • Insulation thickness: 31 mm
  • Water connectionsdiameter: 1/2 M
  • Min Temperature of storage tank room: 1 °C
  • Heat dispersion (Pes) (A): 20 W
  • Available static pressure: 65 Pa
  • Annual energy consumption (average climate) (B): 567 kWh/year
  • Seasonal efficiency (B): 90.6%
  • F-GAS DATA: R134a
  • Refrigerant type: 380
  • Refrigerant charge: Not specified
  • GWP: 1430
  • CO2 equivalents: 0.543 t
  • Article Number: 3623239

Product Description

  • Wall-hung heat pump for domestic hot water production.
  • High performances and sustainability: environmentally friendly heat pump mode to achieve 55°C.
  • Security and durability: Condenser wrapped around titanium enamelled steel boiler, not immersed in water.
  • Operating range in heat pump mode with air temperature from 10 to 40°C
  • Anti corrosion.
Page